Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38658269

RESUMO

OBJECTIVES: We sought to investigate the impact of sex on myocardial perfusion changes following chronic total coronary occlusion (CTO) percutaneous coronary intervention (PCI) as measured by [15O]H2O positron-emission tomography (PET) perfusion imaging. BACKGROUND: CTO PCI has been associated with an increase in myocardial perfusion, yet females are less likely to undergo revascularization. As such, data on the impact of sex on myocardial perfusion following CTO PCI is scarce. METHODS: A total of 212 patients were prospectively enrolled and underwent CTO PCI combined with [15O]H2O PET perfusion imaging prior to and 3 months after PCI. Hyperemic myocardial blood flow (hMBF, mL·min-1·g-1) and coronary flow reserve (CFR) allocated to the CTO territory were quantitatively assessed. RESULTS: This study comprised 34 (16 %) females and 178 (84 %) males. HMBF at baseline did not differ between sexes. Females showed a higher increase in hMBF than males (Δ1.34 ± 0.67 vs. Δ1.06 ± 0.74, p = 0.044), whereas post-PCI hMBF was comparable (2.59 ± 0.85 in females vs. 2.28 ± 0.84 in males, p = 0.052). Female sex was independently associated with a higher increase in hMBF after correction for clinical covariates. CFR increase after revascularization was similar in females and males (Δ1.47 ± 0.99 vs. Δ1.30 ± 1.14, p = 0.711). CONCLUSIONS: The present study demonstrates a greater recovery of stress perfusion in females compared to males as measured by serial [15O]H2O PET imaging. In addition, a comparable increase in CFR was found in females and males. These results emphasize the benefit of performing CTO PCI in both sexes. CLINICAL PERSPECTIVE: What is new? What are the clinical implications?

2.
Catheter Cardiovasc Interv ; 102(5): 844-856, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37671770

RESUMO

BACKGROUND: The Japanese Channel (J-Channel) score was introduced to aid in retrograde percutaneous coronary intervention (PCI) of chronic total coronary occlusions (CTOs). The predictive value of the J-Channel score has not been compared with established collateral grading systems such as the Rentrop classification and Werner grade. AIMS: To investigate the predictive value of the J-Channel score, Rentrop classification and Werner grade for successful collateral channel (CC) guidewire crossing and technical CTO PCI success. METHODS: A total of 600 prospectively recruited patients underwent CTO PCI. All grading systems were assessed under dual catheter injection. CC guidewire crossing was considered successful if the guidewire reached the distal segment of the CTO vessel through a retrograde approach. Technical CTO PCI success was defined as thrombolysis in myocardial infarction flow grade 3 and residual stenosis <30%. RESULTS: Of 600 patients, 257 (43%) underwent CTO PCI through a retrograde approach. Successful CC guidewire crossing was achieved in 208 (81%) patients. The predictive value of the J-Channel score for CC guidewire crossing (area under curve 0.743) was comparable with the Rentrop classification (0.699, p = 0.094) and superior to the Werner grade (0.663, p = 0.002). Technical CTO PCI success was reported in 232 (90%) patients. The Rentrop classification exhibited a numerically higher discriminatory ability (0.676) compared to the J-Channel score (0.664) and Werner grade (0.589). CONCLUSIONS: The J-channel score might aid in strategic collateral channel selection during retrograde CTO PCI. However, the J-Channel score, Rentrop classification, and Werner grade have limited value in predicting technical CTO PCI success.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Angiografia Coronária , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Fatores de Risco , Sistema de Registros
3.
Eur Heart J Cardiovasc Imaging ; 16(4): 410-6, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25345661

RESUMO

AIMS: Three-dimensional (3D) speckle tracking echocardiography (3DSTE) has been shown to be an accurate and reliable clinical tool for the evaluation of global and regional left ventricular (LV) function through strain analysis, but the absence of normal values has precluded its widespread use in clinical practice. The aim of this prospective multicentre study was to establish normal reference values of LV strain parameters using 3DSTE in a large healthy population. METHODS AND RESULTS: A total of 303 healthy subjects (156 males [51%], between 18 and 82 years of age, ejection fraction [EF] 61 ± 3%), stratified to provide approximately equal proportions of healthy subjects of 18-30, 31-40, 41-50, 51-60, and >60 years of age, underwent 3DSTE. Data were analysed for LV volumes, EF, mass, and global and regional circumferential, longitudinal, radial, and area strain. Significant but small differences between men and women were found for longitudinal and area strains, as well as between different age groups for all LV strain parameters. However, large differences in normal values were observed between different segments, walls, and levels of the LV for radial and longitudinal strains, whereas circumferential and area strains demonstrated generally consistent normal ranges across the LV. CONCLUSIONS: Normal ranges of global and regional LV strain using 3DSTE have been established for clinical use. Differences in the magnitude of LV strain are present between men and women as well as different age groups. Moreover, there are differences between different segments, walls, and levels as part of the functional non-uniformity of the normal LV that necessitates the use of segment-specific normal ranges for radial and longitudinal strains. Circumferential and area strains demonstrate the most consistent normal ranges overall.


Assuntos
Ecocardiografia Tridimensional , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Esquerda , Adulto , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Tridimensional/métodos , União Europeia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos
4.
Int J Cardiovasc Imaging ; 30(3): 523-33, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24477358

RESUMO

The aim is to detect early changes in myocardial mechanics in hypertrophic cardiomyopathy (HCM) mutation carriers, three-dimensional speckle tracking echocardiography (3DSTE) was used for screening of family members in the HCM population. Eighty subjects were divided as: HCM mutation carriers (n = 23), manifest HCM patients (n = 28), and normal controls (n = 29). They prospectively underwent 3DSTE for left atrial (LA) and left ventricle (LV) strain analysis. HCM mutation carriers showed significantly higher LA minimum volume (ml/m(2)) (17 ± 6 vs. 14 ± 4, respectively, P = 0.03) and a significantly lower peak atrial longitudinal strain (PALS) (%), (27 ± 5 vs. 31 ± 7, respectively, P = 0.02) when compared to controls. However, no differences were found in global or regional LV systolic myocardial deformation between both groups. Manifest HCM patients, compared to carriers showed significantly higher LA minimum (27 ± 10 vs. 17 ± 6, respectively, P < 0.001) and maximum volume (42 ± 14 vs. 32 ± 8, respectively, P = 0.007) as well as lower LA ejection fraction (%) (35 ± 8 vs. 47 ± 9, respectively, P < 0.001) and PALS (17 ± 5 vs. 27 ± 5, respectively, P < 0.001). Comparing LV strain, HCM patients showed reduced global longitudinal (-11 ± 4 vs. -16 ± 3, respectively, P < 0.001) and area strain (-35 ± 6 vs. -40 ± 5, respectively, P = 0.005). HCM mutation carriers may be distinguished from healthy subjects using 3DSTE through detection of LA dysfunction that may indicate LV diastolic dysfunction. Further research in a larger study population with gene-specific analysis is warranted for potential clinical usefulness of 3DSTE in family screening for HCM.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Adulto , Cardiomiopatia Hipertrófica/fisiopatologia , Feminino , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos
6.
Eur Heart J Cardiovasc Imaging ; 14(7): 700-10, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23111693

RESUMO

AIMS: We directly compared TomTec and QLAB software packages for the three-dimensional echocardiographic (3DE) assessment of left ventricular (LV) dyssynchrony including their ability to predict response to cardiac resynchronization therapy (CRT) in patients with ischaemic and non-ischaemic cardiomyopathy. METHODS AND RESULTS: A total of 140 heart failure patients with the LVEF ≤35% and 60 healthy volunteers underwent 3DE. A subgroup of 60 patients underwent CRT and were evaluated before and 6-12 months after implantation. The systolic dyssynchrony index (SDI) was derived from the dispersion of time to minimum regional volume for all 16 LV segments and measured with both software packages and compared using Pearson's correlation and Bland-Altman analysis. Measurements of SDI were significantly higher using TomTec compared with QLAB in both patients (10.9 ± 3.8 vs. 9.7 ± 3.9, P < 0.001) and healthy volunteers (4.1 ± 0.8 vs. 2.4 ± 1, P < 0.001), with large biases and wide limits of agreement. A moderate correlation (r = 0.65, P < 0.001) was observed between both software packages in patients while their inter-observer and intra-observer reliability were good. Of the 60 patients undergoing CRT, reverse remodelling as a measure of response was observed in 41 patients (68%). The optimal SDI cut-off value to predict response to CRT was higher for TomTec than for QLAB (8.8 vs.7.3%, P < 0.001) and demonstrated better sensitivity and specificity (93 and 61%, respectively) compared with QLAB (88 and 33%, respectively). Response prediction in patients with non-ischaemic cardiomyopathy was excellent with a sensitivity and specificity of 95 and 100% for TomTec and 70 and 83% for QLAB using similar cut-off values of 9.1 and 9.2%, respectively. CONCLUSION: Different 3DE software packages for the assessment of mechanical dyssynchrony should not be used interchangeably until better software standardization is achieved. Dyssynchrony assessment with 3DE for the prediction of response to CRT seems particularly useful in patients with non-ischaemic cardiomyopathy.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Ecocardiografia Tridimensional/instrumentação , Interpretação de Imagem Assistida por Computador , Software , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/terapia , Idoso , Estudos de Casos e Controles , Estudos de Coortes , Ecocardiografia Tridimensional/métodos , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/terapia , Valor Preditivo dos Testes , Valores de Referência , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Volume Sistólico , Sístole , Fatores de Tempo , Resultado do Tratamento , Remodelação Ventricular/fisiologia
7.
Eur J Heart Fail ; 15(3): 299-307, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23183349

RESUMO

AIMS: Invasive assessment of acute haemodynamic response to biventricular pacing has been proposed as a tool to determine individual response and to optimize the effects of CRT. However, the long-term results of this approach have been poorly studied. The present study relates acute haemodynamic effects of CRT to long-term outcome. METHODS AND RESULTS: Forty-one patients were analysed in the present study. During temporary biventricular pacing before implantation, acute changes in LV pump function were assessed by pressure-volume loop measurements and related to long-term response after CRT. In the study population [30 (71%) men, NYHA class 2.9 ± 0.4, EF 28 ± 7%, QRS 150 ± 25 ms], baseline mean stroke work (SW) and dP/dt(max) were 4.6 ± 2.6 L × mmHg and 874 ± 259 mmHg/s, respectively. During biventricular pacing, mean SW and dP/dt(max) increased significantly by 43 ± 39% (+ 2.2 ± 2.4 L × mmHg, P < 0.001) and 13 ± 18% (+ 96 ± 136 mmHg/s, P < 0.001), respectively. In long-term responders (n = 29, 71%) compared with non-responders (n = 12, 29%), the acute increase in SW was significantly higher (+57 ± 33% vs. + 10 ± 30%, P < 0.001), whereas the acute increase in dP/dt(max) was not significantly different between responders and non-responders (+ 15 ± 18% vs. 6 ± 15%, P = 0.139). Receiver operating characteristic (ROC) curve analysis indicated that SW was superior to dP/dt(max), QRS duration and LV dyssynchrony in prediction of response to CRT. A cut-off value for SW of 20% yielded a sensitivity of 90% and specificity of 75% to predict reverse remodelling at 6 months. CONCLUSION: Invasive assessment of acute haemodynamics is a reliable tool to determine individual response to CRT. An acute increase in SW predicts long-term response to CRT with a higher accuracy than an acute increase in dP/dt(max), baseline QRS duration, and degree of LV mechanical dyssynchrony.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Hemodinâmica , Disfunção Ventricular Esquerda/terapia , Idoso , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Prognóstico , Estudos Prospectivos , Curva ROC , Resultado do Tratamento
8.
Eur Heart J Cardiovasc Imaging ; 13(9): 763-75, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22379129

RESUMO

AIMS: In a time of controversy regarding the use of echocardiography for assessment of left ventricular (LV) dyssynchrony and prediction of response to cardiac resynchronization therapy (CRT), this meta-analysis aimed to evaluate the feasibility and reliability of LV dyssynchrony assessment by three-dimensional echocardiography (3DE), determine clinically useful reference values in healthy subjects and heart failure patients, and examine the accuracy of 3DE to predict response to CRT. METHODS AND RESULTS: A total of 73 studies that evaluated the assessment of LV dyssynchrony by 3DE were eligible. The systolic dyssynchrony index (SDI) for 16 segments, being the predominant 3DE dyssynchrony parameter, was used for data pooling. Results demonstrated that LV dyssynchrony assessment by 3DE is feasible in 94% of studied subjects [95% confidence interval (CI): 92-95%)]. Pooled estimates of intraclass correlation coefficients (ICC) and limits of agreement (LoA) demonstrated that SDI has good interobserver (ICC: 0.92, LoA: 4.07%) and intraobserver reliability (ICC: 0.95, LoA: 2.10%). Reference values of SDI in healthy subjects, heart failure patients in general, and patients eligible for CRT were 2.7 ± 0.9%, 9.8 ± 3.9%, and 10.7 ± 3.6%, respectively. Meta-regression analysis demonstrated that reference values of SDI in healthy subjects significantly differed between different software [1.80% (95% CI: 0.55-3.05%), P< 0.001]. In patients eligible for CRT, SDI had good accuracy to predict treatment response with a weighted mean cut-off value of 9.8% and pooled estimates for sensitivity and specificity of 93% (95% CI: 89-97%) and 75% (95% CI: 58-93%), respectively. CONCLUSION: 3DE is a feasible and reliable tool for assessment of LV dyssynchrony and may have additional value to current selection criteria for accurate prediction of response to CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Ecocardiografia Tridimensional , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/terapia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Valor Preditivo dos Testes
9.
Eur Heart J Cardiovasc Imaging ; 13(10): 834-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22345305

RESUMO

AIMS: We evaluated the accuracy of three-dimensional speckle-tracking echocardiography (3DSTE) to evaluate left ventricular (LV) volumes, ejection fraction (EF), and global circumferential strain (CS) in comparison with cardiac magnetic resonance imaging (MRI) in a healthy population. METHODS AND RESULTS: A total of 45 out of 50 consecutive healthy subjects (38 males, age 45 ± 15 years) successfully underwent both 3DSTE and MRI on the same day. Three-dimensional echocardiography data sets were analysed using speckle tracking to measure LV end-diastolic and end-systolic volumes, EF, and global CS. With MRI, the method of discs approximation was used to obtain volumes and the EF, whereas CS was acquired using myocardial tissue tagging. Inter-technique comparisons included regression and the Bland-Altman analysis. For quantification of LV volumes, 3DSTE correlated well with MRI (r: 0.75-0.81), but volumes were significantly underestimated with relatively large biases (13-34 mL) and wide limits of agreement (SD: 11-25 mL). However, excellent accuracy was revealed for measurement of EF by 3DSTE with a good correlation (r: 0.91), minimal bias, and narrow limits of agreement (0.6 ± 1.7%) compared with MRI. For measurement of CS, a large mean bias was found between techniques (10.0%), despite narrow limits of agreement (SD: 1.7%) and a good correlation between techniques (r: 0.80). CONCLUSION: Although 3DSTE-derived LV volumes are underestimated in most patients compared with MRI, measurement of the LVEF revealed excellent accuracy. Measurements of CS were systematically greater (i.e. more negative) with 3DSTE than MRI, which likely reflects various inter-technique differences that preclude direct comparability of their measurements.


Assuntos
Ecocardiografia Tridimensional , Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Função Ventricular Esquerda , Feminino , Ventrículos do Coração/patologia , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estatística como Assunto
10.
Eur Heart J Cardiovasc Imaging ; 13(2): 159-68, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21926118

RESUMO

AIMS: Although the accuracy of three-dimensional speckle tracking echocardiography (STE) to quantify left ventricular (LV) volumes and function has been demonstrated, its reliability has not been studied in great detail. The aim of the study was to determine inter-observer, intra-observer, and test-retest reliability of echocardiographic measurements of LV volumes and function using three-dimensional STE. METHODS AND RESULTS: A total of 140 consecutive patients presenting for routine echocardiographic examination underwent three-dimensional STE. Twenty-three of the 140 patients (16%) were excluded from the analysis due to atrial fibrillation or insufficient image quality. In the remaining 117 patients [69 males, age 59 ± 16 years, ejection fraction (EF) 51 ± 13%], intra-observer and inter-observer reliability of LV volumes, EF, and global and segmental strain measurements was determined, whereas test-retest reliability was assessed in a subgroup of 50 patients. LV volumes and EF measurements demonstrated good reliability [intraclass correlation coefficient (ICC): 0.85-0.99; standard error of measurement (SEM): 3.1-9.2 mL and 1.7-4.0%, respectively]. Reliability of global circumferential strain measurements (ICC: 0.85-0.97; SEM: 1.4-2.6%) was superior to longitudinal (ICC: 0.66-0.92; SEM: 1.0-2.1%) and radial strain measurements (ICC: 0.52-0.88; SEM: 4.4-8.1%), with similar results found for segmental strain measurements (P < 0.001 for all). Reliability was not significantly affected by the image quality or temporal resolution of 3D data sets for any parameter. CONCLUSION: Good intra-observer, inter-observer, and test-retest reliability support the use of three-dimensional STE for routine evaluation of LV volumes and EF. Global and segmental circumferential strain measurements also demonstrate high reliability, whereas analysis by a single observer is currently recommended for longitudinal and radial strain due to limited inter-observer and test-retest reliability.


Assuntos
Ecocardiografia Tridimensional , Ventrículos do Coração/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda , Adulto , Idoso , Algoritmos , Ecocardiografia Tridimensional/métodos , Feminino , Cardiopatias/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Ultrasound Med Biol ; 38(2): 247-52, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22178160

RESUMO

In animal studies, transthoracic ultrasound and microbubbles have shown to dissolve thrombi in ST elevation myocardial infarction (STEMI). To examine this effect in patients, we have initiated the Sonolysis trial. In this pilot study of 10 patients with a first acute STEMI, we investigated the safety and feasibility of this trial. After pretreatment in the ambulance, five patients were randomized to receive microbubbles with three-dimensional (3-D) guided high mechanical index impulses (1.18) for 15 min, whereas the control group received placebo without ultrasound. Subsequently, primary percutaneous coronary intervention (PPCI) was performed, if indicated. All patients successfully underwent study treatment and PPCI. No significant difference between treatment and control group in safety (minor adverse events 2/5 vs. 2/5, p = NS) and outcome (TIMI III flow 3/5 vs. 1/5 respectively, p = 0.23) was recorded. These results demonstrate that the study protocol is feasible in the acute cardiac care setting and safe during treatment and follow-up.


Assuntos
Serviços Médicos de Emergência/métodos , Microbolhas/uso terapêutico , Infarto do Miocárdio/terapia , Terapia Trombolítica/métodos , Terapia por Ultrassom/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Infusões Parenterais , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Resultado do Tratamento , Adulto Jovem
12.
Am J Cardiol ; 108(7): 1038-44, 2011 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-21784385

RESUMO

In an era of rapidly expanding and evolving 3-dimensional echocardiographic (3DE) technology, 1 of the issues facing the 3DE quantification of chamber volumes and function is that different software vendors use different methodologies and algorithms. The aim of this study was to evaluate the comparability and reproducibility of 3DE direct volumetric and speckle-tracking methods for left ventricular (LV) and left atrial (LA) chamber quantification. A total of 120 subjects (mean age 53 ± 17 years, 65% men), including 88 unselected patients and 32 healthy volunteers, underwent 3DE acquisitions and analysis using direct volumetric and speckle-tracking methods successively. Measurements of LV and LA volumes and LV function were compared between the 2 3DE methods. Additionally, intraobserver and interobserver reproducibility was assessed in 40 randomly selected patients. Measurements of LV end-diastolic volume, end-systolic volume, and ejection fraction by 3DE direct volumetric and 3DE speckle-tracking methods were comparable, with good correlations (r = 0.98, r = 0.98, and r = 0.87, respectively), small biases, and narrow limits of agreement (-1 ± 8 ml, -1 ± 8 ml, and 0 ± 6%, respectively). For measurements of LA end-systolic volume and end-diastolic volume, similar correlations (r = 0.96 for both), small biases, and narrow limits of agreement (-2 ± 6 and -1 ± 5 ml, respectively) were found between the 2 methods. Intraobserver and interobserver reproducibility for LV and LA quantification were comparable for the 2 methods. In conclusion, 3DE direct volumetric and speckle-tracking methods give comparable and reproducible quantification of LV and LA volumes and function, making interchangeable application a viable option in daily clinical practice.


Assuntos
Função do Átrio Esquerdo/fisiologia , Volume Cardíaco/fisiologia , Ecocardiografia Tridimensional/métodos , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes
14.
J Am Soc Echocardiogr ; 24(3): 314-21, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21338866

RESUMO

OBJECTIVE: We evaluated the ability of a novel automatic index based on area strain to reliably quantify global and regional left ventricular (LV) function and accurately identify wall motion (WM) abnormalities using three-dimensional speckle tracking echocardiography. METHODS: A total of 140 consecutive patients underwent two- and three-dimensional echocardiography. Segmental WM assessment by area strain was compared with visual assessment of two-dimensional images by two experienced echocardiographers. For global LV function assessment, area strain was validated against LV ejection fraction (EF) and wall motion score index (WMSI). Observer reliability was assessed in all patients, whereas test-retest reliability was evaluated in a subgroup of 50 randomly selected patients. Normal reference values of area strain were determined in 56 healthy subjects. RESULTS: Agreement of WM scores between area strain and visual assessment was found in 94% of normal, 55% of hypokinetic, and 91% of akinetic segments (κ-coefficient 0.88). Sensitivity, specificity, and accuracy of area strain to distinguish abnormal segments from normal segments were 91%, 96%, and 94%, respectively. In regard to global LV function assessment, area strain was highly correlated with EF and WMSI (r = 0.91 and 0.88, respectively). Observer and test-retest reliability of area strain for quantitative assessment of global and regional LV function were good to excellent (all intraclass correlation coefficients ≥0.77). Intraobserver and interobserver reliability of semiquantitative segmental WM analysis by area strain (κ-coefficients 0.87 and 0.73) were comparable to visual assessment by experienced echocardiographers (0.85 and 0.69, respectively). CONCLUSION: Area strain represents a promising novel automatic index that may provide an accurate and reproducible alternative to current echocardiographic standards for quantitative assessment of global and regional LV function. Area strain seems to adequately identify regional wall motion abnormalities compared with the clinical standard of visual assessment by experienced echocardiographers.


Assuntos
Ecocardiografia Tridimensional/métodos , Técnicas de Imagem por Elasticidade/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Adulto , Módulo de Elasticidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estresse Mecânico
15.
J Am Soc Echocardiogr ; 22(9): 1047-54, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19647409

RESUMO

OBJECTIVE: We studied the comparability of left ventricular (LV) mechanical dyssynchrony assessment by tissue Doppler imaging (TDI) and real-time three-dimensional echocardiography (RT3DE) in patients with a wide range of LV ejection fractions and different causes of cardiomyopathy. In addition, we evaluated the ability of both techniques to predict response to cardiac resynchronization therapy (CRT). METHODS: A total of 90 patients and 30 healthy volunteers underwent both TDI and RT3DE. A subgroup of 27 patients underwent CRT and were evaluated before and 6 months after implantation. Mechanical dyssynchrony was measured with TDI using the standard deviation of time to peak systolic tissue velocity of 12 LV myocardial segments. With RT3DE, the standard deviation of time from QRS onset to minimal volume of 16 LV subvolumes was assessed. Indicators of response to CRT were a clinical improvement of >or= 1 New York Heart Association functional class, and reverse remodeling defined as a reduction of >or= 15% in LV end-systolic volume at 6 months. RESULTS: A moderate correlation (r = 0.581, P < .001) was observed between TDI and RT3DE. No significant difference in the presence of mechanical dyssynchrony by TDI and RT3DE was observed (53% vs 48%, respectively). Agreement between techniques was comparable between patients with ischemic and nonischemic cardiomyopathy. However, up to 30% nonagreement between the 2 techniques was found, depending on the severity of LV dysfunction. Of the 27 patients undergoing CRT, clinical response was observed in 70% of patients, whereas reverse remodeling occurred in 63% of patients. All baseline characteristics were similar between responders and nonresponders, except for mechanical dyssynchrony assessed by RT3DE, which was significantly higher in responders compared with nonresponders (10.1% +/- 2.6% vs 5.1% +/- 1.2% for clinical response, P < .001; 10.0% +/- 2.8% vs 6.3% +/- 2.3% for reverse remodeling, P = .001). By applying previously defined cutoff values, receiver operating characteristic curve analysis demonstrated a sensitivity of 58% with a specificity of 50% for TDI and a sensitivity of 95% with a specificity of 87% for RT3DE to predict clinical response to CRT. For prediction of reverse remodeling after CRT, sensitivity and specificity were 59% and 50% for TDI, and 88% and 60% for RT3DE, respectively. The optimal cutoff value for systolic dyssynchrony index by RT3DE of 6.7% yielded a sensitivity of 90% with a specificity of 87% to predict clinical response, and a sensitivity of 88% with a specificity of 70% to predict reverse remodeling. CONCLUSION: Marked differences between techniques are found for the presence of mechanical dyssynchrony when current cutoff values are applied, making interchangeability of these techniques uncertain. Assessment of mechanical dyssynchrony by RT3DE might be an appropriate alternative to TDI for accurate prediction of response to CRT.


Assuntos
Estimulação Cardíaca Artificial/métodos , Ecocardiografia Tridimensional/métodos , Técnicas de Imagem por Elasticidade/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/prevenção & controle , Sistemas Computacionais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
17.
Int J Cardiovasc Imaging ; 25(1): 1-11, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18633727

RESUMO

OBJECTIVES: To compare regional left ventricular (LV) volume curves obtained with real time three-dimensional echocardiography (RT3DE) with two-dimensional circumferential strain curves obtained by MRI in cardiac resynchronization therapy candidates. BACKGROUND: Several methods using either ultrasound or MRI are used to quantify mechanical dyssynchrony (MD). Theoretically, LV volume and circumferential strain seem related, since both measures are connected to the radius of the ventricle. METHODS: In 21 patients with chronic heart failure, RT3DE and tagged MRI were performed subsequently. Regional LV volume was computed from the ultrasound images. From the MR images, regional circumferential strain was calculated. Cross-correlations with time lags of 1% of the cardiac cycle were performed to compare the curves in corresponding LV segments. Furthermore, peak septal to lateral (SL) delays were compared between modalities. RESULTS: High correlations were found between the curves (r(2) = 0.65 +/- 0.19), but regional differences in time delay between modalities were observed. In the septum, the volume curve was earlier than the strain curve by 1.8 +/- 17.0 time-lags (n.s.), while in the lateral wall, the volume curve was earlier by 3.3 +/- 12.0 time-lags (P < 0.02). There was a non-significant difference between SL delays in the two modalities (volume: -1.0 +/- 8.6%, strain: 3.0 +/- 12.7%, P = 0.17, a positive sign indicates that the lateral wall is delayed). CONCLUSIONS: High correlations were observed between both modalities, but regional differences in time-delay were found. This is possibly inherent to the method of echocardiographic volume calculation and hampers the comparison of both measures for the quantification of MD.


Assuntos
Estimulação Cardíaca Artificial , Ecocardiografia Tridimensional , Imageamento por Ressonância Magnética , Disfunção Ventricular Esquerda/diagnóstico , Adulto , Idoso , Estudos de Casos e Controles , Meios de Contraste , Feminino , Gadolínio DTPA , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...